Sanyo DSR-3706PA DVR User Manual


 
Recording settings (User level: ID3)
26 English
It allows you to set HDD recording area management
conditions such as overwrite recording, remaining disk
warning level, automatic erase function, etc.
1 OVERWRITE (Initial setting: ON)
Setting recording conditions to overwrite for the normal
and alarm recording areas.
ON:
When the hard disk becomes full, recording continues
and data is automatically overwritten from the first
images.
The [AREA FULL RESET] button of the normal or
alarm recording area does not appear on the
RECORDING AREA SET screen.
OFF:
The remaining capacity warning indicator of the DVR
starts blinking when the recording area becomes full,
recording stops.
2 REMAINING DISK WARNING
The remaining disk warning buzzer can be programed to
go off when the remaining space available reaches a
specified value if the [OVERWRITE] setting is set to
"OFF" for the normal and alarm recording area.
Now, setting the remaining disk warning level that will set
the warning buzzer on. The set level will apply to both
the normal and alarm recording areas.
Available settings: 1 - 10%
3 SERIES REC (Initial setting: OFF)
Series recording can be set if the multiple DVR units are
connected using the SERIES REC terminal at the rear
panels.
Series recording implies that recording can automatically
continue on the next DVR unit when the recording area
of the first DVR becomes full.
ON: Performing series recording.
OFF: Series recording is not activated.
4 AUTO DELETE (Initial setting: OFF)
It is the automatic erase function of the images saved in
the normal and alarm recording area. The image data
that is older than the specified storage period are
automatically erased.
Selections: OFF, 1, 2, 3 ... 99 DAYS
1 - 99 DAYS: To set the auto delete function and
storage period between 1 and 99 days.
OFF: The images will not be erased automatically.
B
RECORDING CONDITIONS SET
By setting [OVERWRITE] to "ON" when
recording for a long time and the recording
area becomes full, the data will be overwritten
and erased sequentially from the oldest
images. Save necessary images before they
are overwritten.
When the [OVERWRITE] setting of the normal
and alarm recording area is set to "ON","***"
is displayed, the remaining disk warning level
cannot be set.
2
3
4
1
Series recording is only available when
[OVERWRITE] is set to "OFF".
The auto delete function does not apply to
the archive area.
If you use the auto delete function, copy or
download important data before the