Fujitsu M2488 VCR User Manual


 
TAPE UNIT SCSI COMMANDS M2488 PRODUCT GUIDE
4-44 CG00000-011503 REV. A April 1997
52-
53
MSB
Parameter Code 0100h
LSB
54
DU DS=1 TSD=1 ETC=0 TMC=0
Reserved
LP=0
E0h or 60h
55
Parameter Length
08h
56
Cln Req * Reserved Reserved Reserved Reserved Reserved Reserved Reserved
00h
57-
63
MSB
Reserved
00h
LSB
* Note: The Cln Req bit of 1 indicates cleaning is required and a subsequent cleaning cycle has not been
completed. The cleaning required parameter persists across hard resets and power cycles. This bit is
reported as 0 following a successful cleaning cycle.
Table 4-40. Log Sense Page 31h, Track Error Statistics
BITS
DEFAULT
VALUE
BYTES 7 6 5 4 3 2 1 0
0
Reserved Page Code
31h
1
Reserved
00h
2-
3
MSB
Page Length 00D8h
LSB
ERROR STATISTICS BY TRACK
4-
5
MSB
Parameter Code 9001h
LSB
6
DU DS=1 TSD=1 ETC=0 TMC=0 0 LP=0
E0h or 60h
7
Parameter Length 08h
8-
15
MSB
Number of ECC correctable read/write errors detected on track 1
LSB
16-
17
MSB
Parameter Code 9002h
LSB
18
DU DS=1 TSD=1 ETC=0 TMC=0 0 LP=0
E0h or 60h
19
Parameter Length 08h
20-
27
MSB
Number of ECC correctable read/write errors detected on track 2
LSB
28-
29
MSB
Parameter Code 9003h
LSB
30
DU DS=1 TSD=1 ETC=0 TMC=0 0 LP=0
E0h or 60h
Table 4-39. Log Sense Page 0Ch, Sequential-Access Device Page (Continued)
BITS
DEFAULT
VALUE
BYTES 7 6 5 4 3 2 1 0