1-6.6.3 Connect the M2488 and the ACL
Refer to Figure 1-22 through Figure 1-25 during performance of this procedure.
Figure 1-22. Connect the M2488 and the ACL Base
STEP ACTION
1 Place the grounding plate on the front of the M2488 (replaces the front panel). See Figure 1-22.
2 Attach the ACL base to the front of the M2488 using the three Allen screws.
3 Pull operator panel cable through small hole on base.
4 Slide the ACL mechanism into the base. Leave slightly forward for cable connection.
5 Refer to Figure 1-23 and Figure 1-24. Connect the cable to the ACL operator panel cable. Tuck
connector into hole in base. Remove protective sheet from adhesive tape inside the ACL base and
press the operator panel cable to the tape.
6 Attach the interface cable between the connector on the rear of the ACL and the connector on the
front of the M2488.
7 Push the mechanism all the way to the rear of the base. Insert the four screws through the ACL
base into the ACL mechanism and tighten.
8 Replace the ACL cover and tighten the two bottom corner screws (see Figure 1-25).
9 Replace the M2488 top cover and tighten the six screws.