Fujitsu M2488 VCR User Manual


 
MAINTENANCE AND SERVICING M2488 PRODUCT GUIDE
8-26 CG00000-011503 REV. A April 1997
b. Page Code 80h Tests
Table 8-20. Page Code 80h Test Description
TEST
ONLINE
ROUTINE
DESCRIPTION
OPERATOR
INTERVENTION
Self Test 01h The same tests as described in Table 8-19. The
self test is also SCSI Routine 01h.
Loop Write/
Read LVL1 -
Digital Tests
50h Data is written into the data buffer and passed
from the data buffer to the MTU. The MTU
returns the data to the formatter through both the
analog and digital check circuitry. No tape motion
is required.
Loop Write/
Read LVL2 -
Analog Tests
51h Data is written into the data buffer and passed
from the data buffer through the formatter. No
tape motion is required.
Write Data Tests 52h Tape is positioned at Load Point and 4 tones are
written. They are each 4 meters in length and
written with the order of Erase Tone, IBG Tone,
Tape Mark (TM) Tone, and Density ID (DID)
Tone.
A scratch tape must be loaded
prior to running this Online
routine.
Read Date Tests 53h Tape is positioned at Load Point and 4 meters of
Erase Tone, IBG Tone, TM Tone and DID Tone
are written. The tones are read back in reverse
direction and a rewind is performed.
A scratch tape must be loaded
prior to running this Online
routine.
Combination
Tests 1
54h Tape is positioned at Load Point and 4 tones of 4
meters each is written. The tones are; Erase Tone,
IBG Tone, TM Tone and DID Tone. The tape is
then rewound. At Load Point, another 4 tones are
written (same as above), but this time instead of
just rewinding, the tones are read in the reverse
direction.
A scratch tape must be loaded
prior to running this Online
routine.
Combination
Tests 2
57h An ‘all zeroes’ data pattern is replicated in the
data buffer and blocks are written to tape until
Logical EOM is detected. The first block written
is 255 bytes in length. Each succeeding block
length is incremented by one. All data is read in
both the forward and reverse directions.
A scratch tape must be loaded
prior to running this Online
routine.
Medium
Changer - No
Cartridge
Present
C0h Tests the drive logic, photo sensors, loader mech-
anism, and the tachometer pulse generation.
Before running this diagnostic,
the xCL magazine must be
removed.
Medium
Changer - No
Magazine Set
C2h Tests the ACL/FACL loader mechanism and
photo sensors.
Before running this diagnostic,
the xCL magazine must be
removed.
For a FACL, after this diagnos-
tic has been requested, the
TEST button on the FACL
operator panel must be pressed
for this diagnostic to begin.