M2488 PRODUCT GUIDE TAPE UNIT SCSI COMMANDS
April 1997 CG00000-011503 REV. A 4-93
Description of the Page Code 81h
Table 4-90. Page 80h Field Description
BYTE BIT VALUE DESCRIPTION
4 0-7 The Routine in Error field contains the Routine ID of the failing routine. If this
field contains 00h, no errors were detected during the last execution of a SEND
DIAGNOSTIC command.
5 0-7 The Execute Count field contains the number of passes attempted before an error
was detected. If an error is detected on the first pass, this field contains a 1. This
field is reset each time a new (different) routine is started. For example: if the
SEND DIAGNOSTIC command Parameter list contained a pass count of 4 for
Routine 50, and a pass count of 7 for Routine 51, and an error was detected on
the third attempt to execute Routine 51, this field would contain a 3.
6-11 This field contains the Fault Symptom Codes that indicate the cause of the error.
Table 4-91. Page 81h - Online Manufacturing Diagnostic Test Page
BITS
BYTES 7 6 5 4 3 2 1 0
0
Page Code (81h)
1
Reserved
2-3
Page Length (0040h)
4
Routine in error (Routine number)
5
Execute Count (Pass Count)
6-7
First Fault Symptom Code
8-9
Second Fault Symptom Code
10-11
Third Fault Symptom Code
12-15
Expected Data
16-19
Received Data
20-23
Address
24
PESSA ERPA code
25
PESSA FORMAT
26-41
PESSA DATA
42-68
Reserved