Table D-1. Error Recovery
F.S.C # DESCRIPTION
3C80 Diagnostic Test Failure
3CA0 SCSI DMA XFER poll timeout
3CA1 SPC DMA data send (e.g. Read) parity error reported to SCSI manager
3CA2 SPC DMA data receive (e.g. Write) parity error reported to SCSI manager
3CA3 SPC manager reported to SCSI manager that an initiator detected error message was received on DMA
transfer
3CA4 SPC manager reported to SCSI manager that a data xfer error occurred during DMA data transfer
3CA5 SPC manager reported to SCSI manager that a REQ/ACK timeout occurred during DMA data transfer
3CA6 SPC manager reported to SCSI manager that an SPC command timed-out during DMA data transfer
3CAE SPC manager reported to SCSI manager that an unknown SPC error occurred during DMA data transfer
3CAF SCSI manager encountered an unknown error occurred during DMA data transfer
3CB0 Write buffer copy to flash failed
3CB1 NVRAM read failure
3CB2 NVRAM write failure
3CB3 NVRAM allocate failure
3CB4 RM and SPC residual mismatch on read long
3CC0 Sense built after retries done for IDE message
3CC1 Initiator’s message reject message didn’t make sense
3CC2 Initiator’s message didn’t make sense
3CC3 Overlapped commands were attempted
3CC4 REQ/ACK timed-out in MSGIN, retries failed
3CC5 Parity error in MSGOUT, retries failed
3CC6 REQ/ACK timed-out in MSGOUT, retries failed
3CC7 REQ/ACK timed-out in CMD, retries failed
3CC8 Parity error in CMD phase, retries failed
3CC9 Parity error in DATA phase, retries failed