Mitsubishi Electronics DX-TL5716U DVR User Manual


 
108
Event terminal
You can set the functions allocated to the EVENT terminals (1
to 3) on the rear panel.
Step
1 Allocate a function to Event 1 to 3.
[Event 1] corresponds to the EVENT 1 terminal,
[Event 2] to the EVENT 2 terminal, and [Event 3] to
the EVENT 3 terminal.
[REC (edge)]: When the EVENT terminal is
grounded, recording starts.
[REC (level)]: Recording is performed while the
EVENT terminal is being grounded.
[Rec stop]: When the EVENT terminal is grounded,
recording stops.
[Program 1 to 3]: When the EVENT terminal is
grounded, the program registered to Program 1 to
3 is started. When no program is registered, you
cannot select this item.
[ADC]: When the EVENT terminal is grounded, the
recorder cancels the alarm display function and
displays the screen that was displayed before the
alarm display.
[Off]: The recorder does not operate even when the
EVENT terminal is grounded.
Step
2 To check the program les, select [Next] next to
[View the program les].
The registered programs are displayed.
Step
3 To read the program les, select [Execute] next
to [Read program les].
You can read and overwrite the program data copied
to a USB memory device.
You cannot modify 3 programs individually.
Step
4 To delete the program les, select [Execute] next
to [Clear program les].
All the registered program files are deleted. The
events set in [Program 1 to 3] are set to [Off].
Tips
When you execute [Forced stop of program] on the
<Warning display • Ext terminal setting> screen, the
ongoing programs are all terminated forcedly. Forced
termination can be executed while the programs are
running.
The character string speci ed by the program appears
on the screen while the program is running.
On-screen display settings
<Information display setting>
Clock display mode and location
You can set the display mode and position of the clock.
Step
1 Select the clock display mode.
[Mode 1]:
01-01-2009 Thu 00:00:00
[Mode 2]:
01-01-2009 Thu
00:00:00
[Mode 3]: The clock is not displayed.
Step
2 Select the clock display position.
Recorder status and title display
You can select the recorder's operation status to be
displayed.
Step
1 Select the modes you want to display on the
screen.
[Remain 1]: The remaining capacity of the device
selected in [Remain 1] of [Mode-out • Remaining
capacity] is displayed.
[Remain 2]: The remaining capacity of the device
selected in [Remain 2] of [Mode-out • Remaining
capacity] is displayed.
[Status]: The recorder's operation status (playback,
normal recording, alarm recording, emergency
recording, etc.) is displayed.
[Active HDD]: Device being recorded or played
back is displayed.
[Recorder title]: The recorder title you set is
displayed.
The modes you check the boxes are displayed on
the screen.
The display positions of the selected modes are
automatically determined depending on the clock
display position.
Tips
You cannot display [Remain 1] and [Remain 2] when
[HDD] is set to [Off] on the <Mode-out • Remaining
capacity> screen (
page 107).
Various settings (continued)
Setup menu