66
Timer recording settings
<Timer program>
You can make settings for timer recording. By setting the
recording cameras, FPS, and picture quality for normal
recording/alarm recording individually for <Recording A>
to <Recording D>, you can change the recording pattern
instantly by changing [Mode].
Check that the date and present time are set correctly.
Page 105
Set the recording cameras and FPS of <Recording A>
to <Recording D>.
Pages 54 to 58
Close the menu screen.
Press the TIMER button on the front panel
of the recorder.
4
10
11
12
567
REC A REC B REC C REC D Archive
Sun
Mon
Tue
Wed
Thu
Fri
Sat
Hol
00 : 00 06 : 00 12 : 00 18 : 00 24 : 00
Setting
screen
Preparation
Confirmation
screen
Execution
See
step
8 for designating
special days.
See
step
9 for designating
holidays.
step
step
step
step
step step step
Timer program
Day
?
Every
Every
07
07
00
00
24
24
00
00
REC A
Archive
OFF
OFF
1
2
Start End Mode MD
-
-
Step
1 Press the SET UP button on the front panel of
the recorder or left-click the mouse.
or
•
<Main menu> is displayed.
Step
2 Select [Recording setting].
Recording setting
•
The <Recording setting> screen is displayed.
Step
3 Select [Setting] next to [Timer program setting].
Setting
•
The <Timer program> screen is displayed.
Step
4 [Day]
[Sun] to [Sat]: Recording is performed on the
designated day of the week.
[Every]: Recording is performed at the programmed
time everyday.
[SPL1 to 3]: Recording is performed on the days
designated as special day in step 8.
[Holiday]: Recording is performed on the days
designated as holiday in step 9. Holiday program is
performed with the highest priority, regardless of the
program number.
Step
5 [Start], [End]
Set the start time and end time of recording. (The
time is indicated by the 24-hour system.)
Step
6 [Mode]
[REC A] to [REC D]: Recording is performed
according to the settings of <Recording A> to
<Recording D> (
pages 54 to 58).
[Archive]: Data are archived to the archive device.
When you select [Archive], make settings for archive
on the <Archive> screen (
page 83).
[Skip]: The timer recording is suspended temporarily.
(Recording is not performed for the designated
period.)
Notice
• When you archive data by timer recording, set the start
and end times so that the archive time is 10 minutes
or longer.
Recording (continued)