5-5SectionR: Routing Table
89
1, 2, 3... 1. Select “E: Edit” from the Routing Table Menu. The Local Network Table
Screen will be displayed. The Local Network Table Screen can also be dis-
played by selecting “R: Routing table” from the Main Menu.
2. Set the local network table. Use the Cursor Keys to move the cursor to the
desired position, then enter a numeric value with Numeric Keys.
Press the Enter Key to register the entered value and move the cursor to the
next position.
Item Meaning
Loc Netwk Specify the address of the network to which the
Communications Unit or Board installed at the target node
belongs.
The setting range is between 1 and 127.
Be careful not to specify the same network address for more
than one network.
SIOU unit # Specify the unit number of the Communications Unit or
Board that is installed at the target node and is connected to
the local network.
The setting range is between 0 and 15.
With Controller Link, the unit number is set in the following
locations.
Communications Unit: Rotary switch on the front panel of
the Unit for CS1-series, CVM1, and
CV-series PCs
DIP switch pin 4 on the front panel
of the Unit for C200HX/HG/HE
PCs)
(Fixed to 0 for CQM1H PCs.)
Communications Board: Option switch on Controller Link
BIOS (device driver)
Enter the same unit number as the above setting.
Press the F6 (Insert) Key or the Insert Key to insert one blank line before the
cursor line. (You cannot move the cursor until you enter s a value in the “Loc
Netwk” column on the blank line.)
Press the F7 (Delete) Key or the Delete Key to delete the line on which the
cursor is currently positioned.
3. After entering all the necessary values in the local network table, press the
F4 (Pre Pg) Key or the F5 (Nxt Pg) Key. The Relay Network Table Screen will
be displayed.