Installation
309301G 17
Fluid Panel 246838
Connect an air supply line (8) to the 1/4” npt(f) solenoid valve port. The air supply must be fil-
tered to 10 micron to lengthen solenoid valve life.
Connect the fluid supply line (11) to the meter inlet. Connect a fluid dispense line (12) to the
3/8” npt(m) outlet of the dispense valve on the fluid panel. Connect the other end to the dis-
pense valve (9).
Fluid Panel 246839
Connect an air supply line (8) to the 1/4” npt(f) solenoid valve port. The air supply must be fil-
tered to 10 micron to lengthen solenoid valve life.
Connect the fluid supply line (11) to the 3/4” npt(f) meter inlet. Connect a fluid dispense line
(12) to the 3/8” npt(m) outlet of the dispense valve on the fluid panel. Connect the other end to
the dispense valve (9).
Install the Remote Operator Station
Mount the operator station (D) in a convenient location for the operator. Secure it with No. 10
or M5 fasteners through the four 0.22” mounting holes (D1). Connect the cable (D2) to the
fluid panel junction box connector marked
C.
20 ft. (6.1 m) station cable extension 198456 is available.