Setup Mode
309301G 27
Fluid Setup Screen
Use fluid setup to designate the parameters for each fluid you will dispense.
Fluids
Fluid parameters must be set before the fluid can be used in a recipe.
To set up the fluids:
You can have 1-3 fluid panels connected to the ProDis-
pense controller. Setup the fluids for each of your fluid
panels as follows:
1. Type the number for the desired units of measure
(1-5).
2. Type the dispense tolerance percentage (1-99).
3. Type the timeout value in minutes (1-99).
If a dispense does not complete by the end of the
entered value, a Dispense Timeout alarm occurs.
See page 33.
4. Type the fluid meter’s K-factor (cc/pulse).
The K-factors in the table are a starting point. You
can calibrate the meter as instructed on page 28.
5. Repeat steps 1-4 for each additional fluid panel.
6. Press the right arrow key to go to the Recipe
Setup screen.
FLUID SETUP
Fluid 1 Fluid 2 Fluid 3
Units of Measure
1=cc 2=oz 3=Qt
4=Ltr 5=Gal
Tolerance %
Timeout Value (min)
K-factor (cc/pulse)
System Fluids Recipes Meters
Fluid Panel
part no.
Meter Type K-factor
(cc/pulse)
244599 oil/lubricant 4.73
244600 water/antifreeze 25
244601 grease/coating 0.119
246837 grease/coating .061
246838 grease/coating n/a
246839 grease/coating 0.286