Servicing Fluid Panel 244601 and 246837
Replacing Fluid Meter, Solenoid, or Dispense Valve
1. If necessary, purge ProDispense system (page 35).
3. Follow steps 3–5 on page 43 to disconnect meter and solenoid cables from the terminal
block.
4. Disconnect fluid lines from the meter and dispense valve. Disconnect air line from the
solenoid.
5. Remove screw (20) and washer (21) from the meter (4). Remove meter, dispense valve
and solenoid assembly from the fluid panel.
6. If replacing meter (4):
a. Place flats of the solenoid (3) in a vice and unscrew the meter (4).
b. Screw new meter into connector (A).
7. If replacing dispense valve (19):
a. Place flats of the solenoid (3) in a vice and unscrew the meter (4).
b. Unscrew dispense valve (19) from the solenoid (3).
c. Screw new dispense valve into connector (C).
d. Screw the meter into the connector (A).
8. If replacing solenoid (3):
a. Place flats of the solenoid (3) in a vice and unscrew dispense valve and meter
assembly.
b. Screw new solenoid (3) into connector (B).
9. Secure the assembly to the fluid panel with screw (20) and washer (21).
10. Follow steps 8–10 on page 45 to connect meter and solenoid cables to the terminal block.
11. Connect fluid lines to the meter and dispense valve. Connect air line to the solenoid.
2. Relieve pressure (page 24) and turn off controller power switch.
Remove fittings from old components and reinstall in new components as needed.