Installation
20 309301G
Ground the System
ProDispense Controller: Connect a ground wire (G1) to the grounding lug (H1) on the bottom
of the controller. Connect the other end of the ground wire to a true earth ground.
Fluid Panels: Connect a ground wire (G) to the grounding lug (H) on the junction box bracket.
Connect the other end of the ground wire to a true earth ground.
Feed Pumps or Pressure Pots: See your separate pump or pressure pot manual.
Air and Fluid Hoses: Use only grounded hose.
Fluid Supply Container: Ground the container according to your local code.
Solvent Pails Used when Purging: Ground pails according to your local code. Use conductive,
metal pails, placed on a grounded surface. Do not place pails on nonconductive surfaces,
such as paper or cardboard.
Check the Resistance
Have a qualified electrician check the resistance between each ProDispense component and
true earth ground. If the resistance is 1 ohm or greater, a different ground site may be
required. Do not operate the system until the problem has been corrected.
The system must be properly grounded. Follow the instructions here and on page 6.
FIG. 11
456
123
789
.
0
EasyKey
TM
TI1439a
G1
H1
G
H
To reduce the risk of fire, explosion, or electric shock, the resistance between the ProBatch
components and true earth ground must be less than 1 ohm.