Operation Procedures
309301G 35
Purging Fluid
Follow this procedure to purge the fluid lines:
1. Connect the fluid supply line to a solvent supply. Set the fluid supply pressure as low as
possible to avoid splashing.
3. Continue dispensing until fluid lines are clean.
4. Turn the dispense switch to AUTO or [release the dispense valve trigger] to stop dispens-
ing.
5. If you are loading a new material, connect the fluid supply line to the new fluid supply, and
follow the procedure for Loading Fluid Lines.
Emergency Stop
2. To begin purging the lines, direct the fluid outlet into a grounded metal pail, turn the Oper-
ator Station dispense switch to ON [and trigger the dispense valve].
To stop fluid flow at all the fluid panels connected to the
controller, press the Stop button on the controller.
To stop fluid flow at an individual fluid panel, press the
STOP button on the Operator Station connected to the
fluid panel.
RECIPE DISPENSE
ID#
Fluid 1 Fluid 2 Fluid 3
Idle Idle Idle
Target 005.00 ltr 050.00 ltr 010.10 ltr
Actual 000.00 ltr 000.00 ltr 000.00 ltr
Tolerance % 555
Difference % -98 -99 -97
Run Totals Alarms
Stop
STOP
DISPENSE
AUTO ON
DISPENSE
START
ti1359a
STOP