Dispense Mode
309301G 33
Alarm History Screen
Press the left or right arrow key to select Alarms. This screen summarizes the last five
alarms that have occurred.
Out of Tolerance Alarm
This alarm occurs when the current actual dispense is either less than target – tolerance or
greater than target + tolerance.
Dispense Timeout Alarm
The controller stops an active dispense and initiates this alarm when the current dispense is
not finished by the end of the Timeout. Timeout is a value entered during Fluid Setup (page
27).
Invalid K-factor Alarm
This alarm occurs if the meter K-factor is set to zero (00.000).
Memory Failure Alarm
This alarm occurs when the memory has been replaced but not programmed or when the
memory has become corrupt.
Alarms
Press Print key to print an Alarms Report.
ALARMS
Date Time Description Recipe Fluid
03/09 9:39 Invalid K-factor 10 1
03/08 14:32 Out of Tolerance 0 1
03/05 15:01 Timeout 6 2
03/05 8:12 Out of Tolerance 62
03/02 10:59 Invalid K-factor 0 3
Run Totals
Alarms
Print
See page 36 for alarm troubleshooting information.