Honeywell IV REV B DVR User Manual


 
Fusion IV DVR User Guide
________________________________________________________________________________________________________
Document 800-05305V1 Rev B 127
10/11
Setting up the Server to Accept Incoming Communications
In order to access the DVR remotely, the DVR Server must be setup to allow remote
connections.
Disable Remote
Control
Enables/Disables acceptance of remote connections by the DVR server.
Time Out Value Specifies a value (in seconds) to wait for a signal from the Fusion
Remote Client. If a signal is not received by that time, the connection is
dropped.
Center Port Used by the DVR to transfer the connection data.
Image Port Used by the DVR to transfer the image data.
Search Port Used by the DVR to transfer the search data
1. Enter Setup on the DVR.
2. Click the Network tab.
3. Clear the Disable Remote Control check box.
Note If a Firewall is used, it may be necessary to adjust the port settings on both
the DVR and the Firewall. Contact the Network Administrator for more
information.
4. Click OK.
5. Make sure a User account is created. Without a user account, the Administrator
account must be used.
6. The DVR server is now ready to receive incoming connections.