Operation examples
Operation example 1
Setting different number of cameras to REC MODE A and
B for normal recording to switch cameras depending on
the time period and day of the week.
For loading of camera video, see “Relation
of recording operation to the number of cameras and
recording interval settings” on page 82.
< Operation >
• REC MODE A (normal recording with all the cameras) is
set to Monday to Friday from 08:00 to 15:00, and REC
MODE B (normal recording with camera numbers “
1
” and
3
”) is set from 15:00 to 20:00.
• On weekends, REC MODE B (normal recording with cam-
era numbers “
1
” and “
3
”) is set from 08:00 to 17:00.
From Monday
to Friday
Saturday and
Sunday
08:00
17:00
08:00
15:00 20:00
REC MODE A
REC MODE B
REC MODE B
< Setting >
1) <CAMERA TITLE/MEMO SETTING> screen setting
(
see pages 34 and 35)
All the cameras (“
1
” to “
4
”):
Input a title.
4
1
2
3
<CAMERA TITLE/MEMO SETTING>
>>
ENTRANCE
ATM
EXIT
COUNTER
MEMO ••••••••••••••••
CLEAR:BACK
ENTER:CHARACTERS
2) <INITIAL SET UP/INFORMATION> screen setting
AUDIO RECORDING: “OFF” ( see page 48)
<INITIAL SET UP/INFORMATION>
HDD SETTINGS
>>
AUDIO RECORDING OFF
REAR TERMINAL SETTINGS
COMMUNICATION PORT SETTINGS
INFORMATION/SERVICE
3) <HDD SETTINGS> screen setting ( see page 47)
HDD REPEAT REC MAIN: “ON”
<HDD SETTINGS>
>>
HDD REPEAT REC MAIN ON
HDD REPEAT REC SUB OFF
HDD REPEAT PLAY OFF
IM-CHECK PLAY OFF
SEQUENTIAL PLAY OFF
4) <TIMER PROGRAM SETTINGS> screen setting
(
see pages 44 to 46)
SELECTED PATTERN: “P1”
<TIMER PROGRAM SETTINGS>
>>
SELECTED PATTERN P1-SET
HOLIDAY SETTING
REC MODE A
REC MODE B
REC MODE C
REC MODE D
ALARM REC DURATION 5S
5) <RECORD SETTING A> screen setting ( see page
46)
All the cameras (“
1
” to “
4
”):
• PPS, GRADE: Set the desired interval and picture
quality for each camera.
• A-PPS: “- - - - - -”
4
1
2
3
<RECORD SETTING A>
NO PPS GRADE A-PPS A-GRADE
>>
3.125P STD ------ STD
3.125P STD ------ STD
3.125P STD ------ STD
3.125P STD ------ STD
ALARM TYPE ALARM CH
PRE ALARM REC OFF
CLEAR:BACK
<ESTD REC> D H M
6) <RECORD SETTING B> screen setting ( see page
46)
Camera numbers “
1
” and “
3
” only:
PPS, GRADE: Set the desired interval and picture
quality for each camera.
A-PPS: “- - - - - -”
Other cameras:
PPS, A-PPS: “- - - - - -”
4
1
2
3
<RECORD SETTING B>
NO PPS GRADE A-PPS A-GRADE
>>
6.25P SUPER ------ STD
------ STD ------ STD
6.25P SUPER ------ STD
------ STD ------ STD
ALARM TYPE ALARM CH
PRE ALARM REC OFF
CLEAR:BACK
<ESTD REC> D H M
7) <TIMER PROGRAM> screen setting ( see page 44)
PROGRAM NO.1 : “SPL,” “08:00,” “15:00,” “A,” “OFF.”
PROGRAM NO.2 : “SPL,” “15:00,” “20:00,” “B,” “OFF.”
PROGRAM NO.3 : “SAT,” “08:00,” “17:00,” “B,” “OFF.”
PROGRAM NO.4 : “SUN,” “08:00,” “17:00,” “B,” “OFF.”
SPL: “MON - FRI”
<TIMER PROGRAM> P1
DW START END MODE MD
>>
1 SPL 08:00 15:00 A OFF
2 SPL 15:00 20:00 B OFF
3 SAT 08:00 17:00 B OFF
4 SUN 08:00 17:00 B OFF
5 --- --:-- --:-- ---- - 
6 --- --:-- --:-- ---- -
7 --- --:-- --:-- ---- -
8 --- --:-- --:-- ---- -
SPL MON-FRI
When completed with all the settings above and after
clearing the menu screen, press both the TIMER ON/
OFF buttons. The unit switches to the timer
programming mode.