Mitsubishi Electronics DX-NT400E DVR User Manual


 
65
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations
ENGLISH
<ALARM SKIP SEARCH>
>>
EXECUTE(FORWARD)
EXECUTE(REVERSE)
PUSH SEARCH KEY FOR
SEARCH SELECTION
6. To stop playback or still-frame playback, press the STOP button.
During still frame playback, to choose the desired video from the
SPLIT4 screen display and display the video of that camera number in
the single screen display, press the SEARCH button to clear the search
screen first, and then press the SPLIT/SINGLE button and the +, – button.
The search may not be performed properly at times depending on
the recorded condition of the index signals.
ALARM SKIP SEARCH
Searches the point where the index signal of alarm recording is written and
plays back approximately 4 seconds where an index signal is written.
<ALARM SKIP SEARCH> In case of forward direction
SKIP COUNT
0302
01
Alarm
Recording
Alarm
Recording
Alarm
Recording
Index signalIndex signalIndex signal
Search SearchSearch Search
Present position
Approx. 4 sec.
play
Approx. 4 sec.
play
Approx. 4 sec.
play
1. Press the SEARCH button.
The search screen selected in “SEARCH TYPE” appears.
2. (When the desired search screen is not displayed on the screen • • • )
Change the “SEARCH TYPE” setting and then press the CLEAR button to display
the “ALARM SKIP SEARCH” screen.
3. Select “EXECUTE(FORWARD)” or “EXECUTE(REVERSE)” and determine such
setting.
“EXECUTE(FORWARD)”: Searches in the forward direction.
“EXECUTE(REVERSE)”: Searches in the reverse direction.
To cancel searching, press the SEARCH button twice.
The search result of the alarm skip search is displayed in the SPLIT4 screen display
regardless of “SELECTION CAMERA NUMBER” setting.
To return to the normal screen, press the SEARCH button twice.
When executing the alarm skip search in the SPLIT4 screen display,
to choose the desired video from the SPLIT4 screen display and display
the video of that camera number in the single screen display, press the
SPLIT/SINGLE button and then press the +, – button.
4. Press the PAUSE button and then press the PLAY button when the desired
video is displayed.
5. To stop ALARM SKIP SEARCH, press the STOP button.
When executing the alarm skip search in the reverse direction with
index signals of less than 4 seconds, that portion may be played back
repeatedly. In this case, press the STOP button to stop the search and
execute alarm skip search in the reverse direction again after the
particular portion has been passed using reverse playback, etc.
The search may not be performed properly at times depending on
the recorded condition of the index signals.