Sony HDW-D1800 VCR User Manual


 
90
9-4 Items in the Extended Setup Menu
Chapter 9 Setup Menus
618 UPCONV
EMBEDDED VITC
(HDW-D1800 only.
Invalid in 24PsF or
23.98PsF mode.)
Select the source for HDSDI embedded VITC which is output after up-conversion during
playback of SD-format tape.
VITC
: Select VITC recorded on SD-format tape.
LTC: Select LTC recorded on SD-format tape.
620 TC CONVERT 24F ->
25F (In 50i or 25PsF
mode only.)
Select whether to convert playback timecode to 25F timecode during playback of tape
recorded in 24PsF or 23.98PsF mode.
OFF
: Do not convert timecode.
ON: Convert timecode.
TC CONVERT 25F ->
24F (In 24PsF or
23.98PsF mode
only.)
Select whether to convert playback timecode to 24F timecode during playback of tape
recorded in 50i or 25PsF mode.
OFF
: Do not convert timecode.
ON: Convert timecode.
621 24F STARTING TC
SEL (In 50i or 25PsF
mode only)
Select one of the following settings for 24F starting TC for timecode conversion from
24F to 25F.
OFF
: Do not set.
ON: Set.
To set the 24F starting TC
Select F9 (SET) with this menu item displayed in the menu display, to enter the starting
TC setting mode. Select F1 (PREV) or F2 (NEXT) for digit selection. When all required
digits have been set correctly, select F9 (SET) again to save the starting TC and exit the
starting TC setting mode.
25F STARTING TC
SEL (In 24PsF or
23.98PsF mode only)
Select one of the following settings for 25F starting TC for timecode conversion from
25F to 24F.
OFF
: Do not set.
ON: Set.
To set the 25F starting TC
Select F9 (SET) with this menu item displayed in the menu display, to enter the starting
TC setting mode. Select F1 (PREV) or F2 (NEXT) for digit selection. When all required
digits have been set correctly, select F9 (SET) again to save the starting TC and exit the
starting TC setting mode.
622 24F JUMPING TC
SEL (In 50i or 25PsF
mode only)
Select one of the following settings for 24F jumping TC for timecode conversion from
24F to 25F.
–3H
: Set JUMPING TC to “STARTING TC –3H”.
–2H: Set JUMPING TC to “STARTING TC –2H”.
–1H: Set JUMPING TC to “STARTING TC –1H”.
+1H: Set JUMPING TC to “STARTING TC +1H”.
+2H: Set JUMPING TC to “STARTING TC +2H”.
+3H: Set JUMPING TC to “STARTING TC +3H”.
0H: Set JUMPING TC to “STARTING TC”.
25F JUMPING TC
SEL (In 24PsF or
23.98PsF mode only)
Select one of the following settings for 25F jumping TC for timecode conversion from
25F to 24F.
–3H
: Set JUMPING TC to “STARTING TC –3H”.
–2H: Set JUMPING TC to “STARTING TC –2H”.
–1H: Set JUMPING TC to “STARTING TC –1H”.
+1H: Set JUMPING TC to “STARTING TC +1H”.
+2H: Set JUMPING TC to “STARTING TC +2H”.
+3H: Set JUMPING TC to “STARTING TC +3H”.
0H: Set JUMPING TC to “STARTING TC”.
630 SEARCH TYPE
SELECT
ALL
: Search all shot marks during index search.
REC: Search recording start marks during index search.
SHOT1: Search shot mark 1 during index search.
SHOT2: Search shot mark 2 during index search.
POST: Search post marks during index search.
Menu items in the range 600 to 650, relating to the timecode generator (Continued)
Item number Item name Settings