Sony HDW-D1800 VCR User Manual


 
92
9-4 Items in the Extended Setup Menu
Chapter 9 Setup Menus
654 UMID GENERATE
METHOD
Select the Instance Number. generation method when the UMID is inherited.
COPY No.+16bit PRS
: Copy No. + 16-bit random number
24bit PRS: 24-bit random number
Note
When menu item 656 is set to “NEW” (an Instance Number indicating that “this is the
original” is generated), the same value (all zeros) is generated regardless of which of
the above methods is selected.
655 UMID RECORDING Select the UMID type to be recorded to tape.
off
: Do not record UMID.
BASIC: Record Basic UMID.
EXTND: Record Extended UMID.
656 MATERIAL NO. Select whether to inherit the UMID in the input signal when recording a UMID.
INPUT
: Inherit the UMID in the input signal, if it is contained.
Even when “INPUT” is selected, a new UMID is generated if the input signal does
not contain UMID data (same as when “NEW” is selected).
When recording with inherited data, the Instance Number is newly generated
according to menu item 654 and changed to a value that indicates that “this is a
copy”.
When the UMID in the input signal is a Basic UMID, the Basic UMID is recorded,
even if menu item 655 is set to “EXTND”.
When the UMID in the input signal is an Extended UMID, the recorded UMID
follows the setting of menu item 655.
NEW: Generate a new UMID, regardless of whether or not the input signal contains a
UMID.
The Basic section does not change during recording.
An Instance Number indicating that “this is the original” is generated.
The Source Pack Date/Time (when) changes with each frame.
The Source Pack Spatial Co-ordinates (where) are not recorded.
The Source Pack Stored Ownership (who) can be set. (See the section “To set
Stored Ownership” (page 60)).
Menu items in the range 700 to 799, relating to video control
Item number Item name Settings
703 BLANK LINE SELECT Select blanking on or off for individual lines in the vertical blanking interval of the
SD video signal.The Y/C signal and odd/even fields are blanked simultaneously.
Sub-Item
0ALL LINE - - -
: Specify the blanking for each line individually.
BLANK: Regardless of the setting of other sub-items, blank all lines which can be
specified in this menu item.
THROU: Regardless of the setting of other sub-items, switch off blanking for all
lines which can be specified in this menu item.
In 59.94i
mode (59.94i
or 29.97PsF)
12 ...
19
LINE 12 ... LINE 19 Specify blanking for lines 12 to 19.
BLANK
: Carry out blanking.
THROU: Switch off blanking.
20 LINE 20 Specify blanking for line 20.
BLANK
: Carry out blanking.
HALF: Carry out half-blanking.
THROU: Switch off blanking.
In 50i mode
(50i or
25PsF)
9 ...
22
LINE 9 ... LINE 22 Specify blanking for lines 9 to 22.
BLANK
: Carry out blanking.
THROU: Switch off blanking.
23 LINE 23 Specify blanking for line 23.
HALF
: Carry out half-blanking.
THROU: Switch off blanking.
Menu items in the range 651 to 699, relating to the UMID (Continued)
Item number Item name Settings