TANDBERG E5714 Flat Panel Television User Manual


 
Operating the Equipment Locally
Page 4-118 Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder
ST.TM.E10076.3
Teletext Stream Option
To access the Teletext Stream option, press the Teletext Stream softkey
in the IRD Data Menu. This is used to select the Teletext stream to be
decoded, from those present in the selected service.
4.14.11 IRD System Status Menu
The IRD System Status Menu has a number of options which are status
only and cannot be changed:
· TS
· Network Name
· Network ID
· Services
· Current Service ID
· Current TS ID
· Current ON ID
· App Version
· Part Number
4.15 Errors Menu
4.15.1 Overview
From the 2U Encoder the Errors Menu can be selected from the Advanced
Menu by pressing the Errors softkey. From the 1U Encoder the Errors
Menu can be selected from the Main Menu by selecting the Errors option.
New errors are reported to the front panel display approximately every
30 seconds.
4.15.2 Active Errors Option
To access the Active Errors option, press the Active Errors softkey in the
Errors Menu. This gives a list of any current errors.
4.15.3 Error Masks Menu
Status of Error Masks
To access the Error Masks option, press the Error Masks softkey in the
Error Masks Menu. This allows any of the error messages to be masked.
There are three states for the error message: Alm, Fail or Off.
· Alm (Alarm) shows the error message and triggers the alarm relay
· Fail shows the error message and triggers both the fail and alarm
relays
· Off does not show the error message and does not trigger any relays
Refer to Annex H, Error Messages for details of all the error messages.
Press the softkey next to a message. As the key is pressed the status of
the message changes.