Error Messages
Page H-8 Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder
ST.TM.E10076.3
Error Message Action to Take
Level Clipping Left
Level Clipping Right
Audio input level on the reported channel is too high and is being clipped.
Reduce the audio input level.
Embedded Source 1
Embedded Source 2
Embedded Source 3
Embedded Source 4
AC-3 Input Invalid
No Digital Input
Check the audio input cable is correctly fitted, and that the audio source is
functioning. If the fault persists call Service Engineer.
Mux FIFO Overflow
Duplicate PID
Invalid PID
Mux Bit-Rate too low
Audio Un-Calibrated
Power Encoder off, then check that the Base Board and any audio modules are
firmly seated in the chassis. Do this by firmly pressing them from the rear of the
Encoder into the chassis. Power on the Encoder. If the fault persists call Service
Engineer.
H.10 Satellite Modulator Related Errors
Table H.8: Satellite Modulator Error Messages
Error Message Action to Take
Config Update
Processor Stopped
Hardware Fault
FPGA Configuration
FPGA Temperature
DLL Unlocked
Module Uncalibrated
Modulation Fault
Synthesiser Unlocked
ALC Error
Input Clock Fault
Input Sync Fault
TSI FIFO
DPC FIFO
Parameter Fault
IF Card Missing
Power Encoder off, then check that the Base Board and Satellite Modulator are
firmly seated in the chassis. Do this by firmly pressing them from the rear of the
Encoder into the chassis. Power on the Encoder. If the fault persists call Service
Engineer.