TANDBERG E5714 Flat Panel Television User Manual


 
Technical Specification
Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder Page B-13
ST.TM.E10076.3
B.4 Control and Monitoring
B.4.1 Remote Control - Ethernet 1 and 2
Table B.21: Ethernet Specification
Item Specification
Safety status SELV
Connector designation ETHERNET#1 and ETHERNET#2
Connector type 8-way RJ-45 socket, 10BaseT (ISO 882/3)
B.4.2 Local Control
Local control is by means of the front panel keypad and LCD display.
B.4.3 Alarm
Table B.22: Alarm Specification
Item Specification
Safety status SELV
Connector designation ALARM
Connector type 9-way D-type male
Alarm contacts Change-over contacts (5 W in common)
Fail contacts Change-over contacts (5 W in common)
Reset contacts Short pins 9 and 5 (resets the Encoder)
Relay Contact Rating
Maximum switching power 30 W
Maximum switching voltage 110 V
Maximum switching current 1 A
B.4.4 Remote Control
This connector provides an RS-232/RS-485 user interface control port that
allows the unit to be controlled by an external master.
Table B.23: Remote Control Specification
Item Specification
Safety status SELV
Connector designation
REMOTE CONTROL
Connector type 9-way D-type male
B.4.5 RS-232 Data (Asynchronous)
RS-232 is not currently supported on the Base Board in Build version 2.0.0
but it is in the option module M2/EOM2/DAT.