Command :MACHine{1|2}:WLISt:INSert [<module_spec>,]
<label_name>[,{<bit_id>|OVERlay|ALL}]
The INSert command inserts waveforms in the timing waveform display. The
waveforms are added from top to bottom up to a maximum of 96 waveforms.
Once 96 waveforms are present, each time you insert another waveform, it
replaces the last waveform.
The first parameter specifies from which module the waveform is coming
from; however, the 1660A-series logic analyzers are single-module
instruments. Therefore, this parameter is not needed. It is described here as
a reminder that programs for the 16500A logic analysis system can be used.
The second parameter specifies the label name that will be inserted. The
optional third parameter specifies the label bit number, overlay, or all. If a
number is specified, only the waveform for that bit number is added to the
screen.
If you specify OVERlay, all the bits of the label are displayed as a composite
overlaid waveform. If you specify ALL, all the bits are displayed sequentially.
If you do not specify the third parameter, ALL is assumed.
<module_spec> {1|2|3|4|5|6|7|8|9|10} (not needed)
<label_name> String of up to 6 alphanumeric characters
<bit_id> An integer from 0 to 31