Agilent Technologies 1660AS TV Converter Box User Manual


 
<pod_num> {{1|2}|{3|4}|{5|6}|{7|8}} 1 through 8 for the HP 1660A, 1 through
6 for the HP 1661A, 1 through 4 for the HP 1662A, and 1 through 2 for the HP
1663A.
<set_hold_
value>
An integer {0|1|2|3|4|5|6|7|8|9} representing the setup and hold
values in table 15-2.
Table 15-2
Setup and hold values
For one clock and one
edge
For one clock and both
edges
For multiple clocks
0 = 3.5/0.0 ns 0 = 4.0/0.0 0 = 4.5/0.0
1 = 3.0/0.5 ns 1 = 3.5/0.5 1 = 4.0/0.5
2 = 2.5/1.0 ns 2 = 3.0/1.0 2 = 3.5/1.0
3 = 2.0/1.5 ns 3 = 2.5/1.5 3 = 3.0/1.5
4 = 1.5/2.0 ns 4 = 2.0/2.0 4 = 2.5/2.0
5 = 1.0/2.5 ns 5 = 1.5/2.5 5 = 2.0/2.5
6 = 0.5/3.0 ns 6 = 1.0/3.0 6 = 1.5/3.0
7 = 0.0/3.5 ns 7 = 0.5/3.5 7 = 1.0/3.5
N/A 8 = 0.0/4.0 8 = 0.5/4.0
N/A N/A 9 = 0.0/4.5
Example OUTPUT XXX;":MACHINE2:SFORMAT:SETHOLD 1,2"
Query :MACHine{1|2}:SFORMAT:SETHOLD? <pod_num>
The SETHold query returns the current setup and hold settings.
Returned Format
[:MACHine{1|2}:SFORmat:SETHold <pod_num>] <set_hold_value><NL>
Example OUTPUT XXX;":MACHINE2:SFORMAT:SETHOLD? 3"
SFORmat Subsystem
SETHold
15–14