TPOSition
Command :MACHine{1|2}:TTRigger:TPOSition
{STARt|CENTer|END|DELay, <time_val>|
POSTstore,<poststore>}
The TPOSition (trigger position) command allows you to set the trigger at
the start, center, end or at any position in the trace (poststore). Poststore is
defined as 0 to 100 percent with a poststore of 100 percent being the same as
start position and a poststore 0 percent being the same as an end trace.
<time_val>
real number from either (2 × sample period) or 16 ns whichever is greater to
(1048575 × sample period).
<poststore> integer from 0 to 100 representing percentage of poststore.
Examples OUTPUT XXX;":MACHINE1:TTRIGGER:TPOSITION END"
OUTPUT XXX;":MACHINE1:TTRIGGER:TPOSITION POSTstore,75"
Query :MACHine{1|2}:TTRigger:TPOSition?
The TPOSition query returns the current trigger position setting.
Returned Format
[:MACHine{1|2}:TTRigger:TPOSition] {STARt|CENTer|END|DELay,
<time_val>|POSTstore,<poststore>}<NL>
Example OUTPUT XXX;":MACHINE1:TTRIGGER:TPOSITION?"