Agilent Technologies 1660AS TV Converter Box User Manual


 
DATA
Query :MACHine{1|2}:SLISt:DATA?
<line_number>,<label_name>
The DATA query returns the value at a specified line number for a given
label. The format will be the same as the one shown in the listing display.
Returned Format
[:MACHine{1|2}:SLISt:DATA] <line_number>,<label_name>,
<pattern_string><NL>
<line_number>
integer from 8191 to +8191
<label_name> string of up to 6 alphanumeric characters
<pattern_
string>
"{#B{0|1|X} . . . |
#Q{0|1|2|3|4|5|6|7|X} . . . |
#H{0|1|2|3|4|5|6|7|8|9|A|B|C|D|E|F|X} . . . |
{0|1|2|3|4|5|6|7|8|9} . . . }"
Example OUTPUT XXX;":MACHINE1:SLIST:DATA? 512, RAS"
LINE
Command :MACHine{1|2}:SLISt:LINE <line_num_mid_screen>
The LINE command allows you to scroll the state analyzer listing vertically.
The command specifies the state line number relative to the trigger that the
analyzer highlights at the center of the screen.
<line_num_mid_
screen>
integer from 8191 to +8191
Example OUTPUT XXX;":MACHINE1:SLIST:LINE 0"
SLISt Subsystem
DATA
17–9