Agilent Technologies 1660AS TV Converter Box User Manual


 
PATTern
Command :MACHine{1|2}:SYMBol:PATTern <label_name>,
<symbol_name>,<pattern_value>
The PATTern command allows you to create a pattern symbol for the
specified label. Because don’t cares (X) are allowed in the pattern value, it
must always be expressed as a string. You may still use different bases,
though don’t cares cannot be used in a decimal number.
<label_name> string of up to 6 alphanumeric characters
<symbol_name> string of up to 16 alphanumeric characters
<pattern_value> "{#B{0|1|X} . . . |
#Q{0|1|2|3|4|5|6|7|X} . . . |
#H{0|1|2|3|4|5|6|7|8|9|A|B|C|D|E|F|X} . . . |
{0|1|2|3|4|5|6|7|8|9} . . . }"
Example
OUTPUT XXX;":MACHINE1:SYMBOL:PATTERN STAT,
MEM_RD,#H01XX"
RANGe
Command :MACHine{1|2}:SYMBol:RANGe <label_name>,
<symbol_name>,<start_value>,<stop_value>
The RANGe command allows you to create a range symbol containing a start
value and a stop value for the specified label. The values may be in binary
(#B), octal (#Q), hexadecimal (#H) or decimal (default). You can not use
don’t cares in any base.
SYMBol Subsystem
PATTern
25–6