Agilent Technologies 1660AS TV Converter Box User Manual


 
TMINimum
Query :MACHine{1|2}:TWAVeform:TMINimum?
The TMINimum query returns the value of the minimum time between the X
and O markers. If there is no valid data, the query returns 9.9E37.
Returned Format [:MACHine{1|2}:TWAVeform:TMINimum] <time_value><NL>
<time_value> real number
Example OUTPUT XXX;":MACHINE1:TWAVEFORM:TMINIMUM?"
TPOSition
Command :MACHine{1|2}:TWAVeform:TPOSition
{STARt|CENTer|END|DELay,<time_val>|
POSTstore,<percent>}
The TPOSition command allows you to control where the trigger point is
placed. The trigger point can be placed at the start, center, end, at a
percentage of post store, or at a value specified by delay. The post store
option is the same as the User Defined option when setting the trigger
point from the front panel.
The TPOSition command is only available when the acquisition mode is set to
manual.
<time_val> real number from 0 to 500 seconds
<percent> integer from 1 to 100
Example OUTPUT XXX;":MACHINE2:TWAVEFORM:TPOSITION CENTER"
TWAVeform Subsystem