Dell 4200 Home Theater Server User Manual


 
3-6 Dell PowerEdge 4200 Systems Service Manual
Real-time
clock error
The RTC on the sys-
tem board may be
malfunctioning.
Run the System Set
Test Group to deter-
mine whether the
RTC on the system
board is faulty.
Resource
conflict
Warning:
IRQ not ini-
tialized
Expansion
ROM not ini-
tialized
The BIOS detected a
resource conflict
while configuring a
Plug and Play ISA
or PCI expansion
card.
See “Resolving
Resource Conflicts”
in Chapter 5 in the
User’s Guide.
Stepping of
CPU is less
than C0 -
System
halted!
A Pentium II micro-
processor that is not
supported by the
system is installed.
Replace the micropro-
cessor with a correct
version of the
Pentium II micropro-
cessor from Dell.
Stepping of
CPU1 is less
than C0 -
System
halted!
An Intel Pentium II
microprocessor that
is not supported by
the system is
installed in the
PROC_1 socket.
Replace the micropro-
cessor with a correct
version of the
Pentium II micropro-
cessor from Dell.
Stepping of
CPU2 is less
than C0 -
System
halted!
A Pentium II micro-
processor that is not
supported by the
system is installed in
the PROC_2 socket.
Replace the micropro-
cessor with a correct
version of the
Pentium II micropro-
cessor from Dell.
System bat-
tery is dead
- Replace
and run
Setup
The battery on the
system board is
dead.
Replace the battery on
the system board, and
run the System Setup
program to restore the
system configuration
information.
System
cache error
- cache dis-
abled
The microprocessor
chip on the system
board may be mal-
functioning.
Run the System Set
Test Group to deter-
mine whether the
microprocessor chip
is faulty.
Table 3-2. System Error Messages
(continued)
Message Cause Action