Mitsubishi Electronics DX-TL1600EM DVR User Manual


 
49
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
Operations
ENGLISH
3) Settings for TIMER PROGRAM are made as follows.
• Designate Monday to Friday as the days of operation
(SPECIAL DW). Then, in Program #1, set the action (MODE)
to “A– 1” for 08:00 to 15:00 on the designated days(SPL).
• In Program #2, set the action to “B– 1” for 15:00 to 20:00 on
the designated days.
• In Program #3, set the action to “B– 1” for 08:00 to 17:00 on
Saturday.
• In Program #4, set the action to “B– 1” for 08:00 to 17:00 on
Sunday.
• In Program #5, set the action to “EJECT” for Sunday’s start-
time of 00:00 to end-time of 05:00.
Upon completing the above settings, press the unit’s TIMER
REC button to initiate Timer operation.
Operation example 4
This is an operation example of a Timer setting that com-
bines NORMAL REC with Alarm Recording using MOTION
DETECTION.
System configuration
Settings are entered so that the backups are created every
Monday morning between 00:00 and 05:00. To facilitate
the exchange of the storage medium after the backup has
been completed, MODE is set to “EJECT”.
Cameras in SELECT REC MODE (A) are set to operate
from 08:00 to 15:00 on Monday through Friday. Set the
unit on POWER from 15:00 to 08:00 the next morning.
Cameras in SELECT REC MODE (B) are set to operate
from 08:00 to next day 08:00 on Saturday and Sunday.
The overall schedule is as shown in the following chart.
Monday
00 : 00
00 : 00
05 : 00
Saturday and Sunday
08 : 00
08 : 00
24 : 00
Monday to Friday
08 : 00 15 : 00
Archive
SELECT REC MODE (A)
24 : 00
POWER
POWER
00 : 00
SELECT REC MODE (B)
replace archive medium
SELECT REC MODE (B)
Settings
1) Enter the same settings for the camera operation set-
ting A as those for operation example 3 in the following: the
CAMERA TITLE setting (on the <MPX DISPLAY> menu),
DEFINE GROUP SETTING (on the <NORMAL REC SET-
TING> menu), and recording conditions. Set the power set-
ting that uses MOTION DETECTION as follows.
• Set IMAGE QUALITY to “HIGH”.
• Set MAX REC FIELDS to “1F”.
• Set A-REC DURATION to “5M”.
• Set RECORD ALARM to “ALL”.
• Set PRE A-REC to “MEDIUM”.
• On the <DEFINE ALARM GROUP> menu, set the cameras
Q,W,E,I,O,} and w.
<DEFINE ALARM GROUP>
CH PRI FILD CH PRI FILD
@Q 2
0.11 O 1 0.22
W 1
0.22 P -
E 1
0.22 { -
R -
} 1 0.22
T -
q -
Y -
w 1 0.22
U -
e -
I 2
0.11 r -
2) Settings for MOTION DETECTION SETTING are made
as follows.
To make the M-DET SETTING, first turn the MOTION
DETECTION setting “ON” in the <INITIAL SET UP> menu.
• Using SELECTION CAMERA NO., set each of the following
camera numbers Q, W, E, I, O, } and w as follows.
• Set CH.MOTION DETECTION to “ON”.
• Set SET DETECTION MASK, SENSITIVITY, MOTION
THRESHOLD TEST MODE.
<MOTION>
@SELECTION CAMERA NO. 1
CH.MOTION DETECTION ON 
SET DETECTION MASK
SENSITIVITY HIGH
MOTION THRESHOLD 5 
TEST MODE OFF
3) Settings for TIMER PROGRAM are made as follows.
• Select “P1” for the setting “SELECTED PATTERN” in the
<TIMER PROGRAM> menu and select “ON” for the setting
“REC MODE (POWER)” in the <M-DET APPLICATION> menu.
<TIMER PROGRAM>
SELECTED PATTERN
DEFINE P1
DEFINE P2
DEFINE P3
<M-DET APPLICATION>
REC MODE (A) OFF
REC MODE (B) OFF
REC MODE (C) OFF
@REC MODE (POWER) ON
P1
• Designate Monday to Friday as the days of operation
(SPECIAL DW). Then, in Program #1, set the action (MODE)
to “A– 1” for 08:00 to 15:00 on the designated days(SPL).
• In Program #2, set the action to “POWER” for 15:00 to 08:00
the next morning.
• In Program #3, set the action to “POWER” for 08:00 to 08:00
the next morning.
• In Program #4, set the action to “POWER” for 08:00 to 08:00
the next morning.
• In Program #5, set the action to “EJECT” for Sunday’s start-
time of 00:00 to end-time of 05:00.
Upon completing the above settings, press the unit’s TIMER
REC button to initiate Timer operation.