Black Box A/C-7S RO Cable Box User Manual


 
111
A/C-7P RO, A/C-7S RO
3.Send that command to the
printer (press the Print Screen
Button or print the
document/file that contains the
Host/PC download command).
4.Send the host data in question to
the printer.
5.To stop the EBCDIC hex dump,
type “&%Z42,2” on the screen,
then send it to the printer (press
the Print Screen Button or print
the document/file that contains
the Host/PC download
command).
Start the EBCDIC hex dump from
the A/C-7 RO’s front panel as
follows:
1.With the A/C-7 RO powered on,
set configuration switch SW1:1
(far left) to “o”, and switch
SW1:8 (far right of first switch
bank) to “|”. The A/C-7 RO is
now in buffer print mode.
2.Return configuration switch
SW1:8 to the “o” position after
printing is completed.
7.3 ASCII Hex Dump
The A/C-7 RO can be set up to print
the buffer in hexadecimal ASCII
code. This differs from the EBCDIC
hex dump in that the buffer is first
translated into ASCII code before it
is printed. This can be useful to
diagnose problems with the interface
or the printer. The ASCII Hex
Dump can only be started through
the A/C-7 RO’s configuration
switches. To start the ASCII Hex
Dump:
1.Locate configuration switches
SW1:4, SW1:5, SW1:6, and SW1:7
on the first switch bank.
2.Write down their current
position (“o” or “|”).
3.With the A/C-7 RO powered on,
set the configuration switches
SW1:4, SW1:5, SW1:6, and SW1:7
to “|”. The A/C-7 RO is now in
ASCII Hex Dump mode.
4.To end ASCII Hex Dump mode,
return the switches to their
original position (see Step 2).