Black Box A/C-7S RO Cable Box User Manual


 
42
A/C-7P RO, A/C-7S RO
COMMAND 34: INTERVENTION
REQUIRED (IR) TIMEOUT
Sets the time interval before an
intervention required signal is sent
to the host after a printer error
occurs.
VALUE DESCRIPTION
000 Never send an IR
001 IR is sent (value *5)
to seconds after
255 printer error occurs
*120 Default, send IR
after ten minutes.
Example: &%Z34,036 sets IR time
interval to 3 minutes (36 *5)/60 = 3
minutes.
COMMAND 36: SUPPRESS IBM
CONTROL CODES
This function is used to select
suppression of all or some IBM
control codes sent from the host
system.
VALUE DESCRIPTION
*0 Obey all IBM
control codes
1 Suppress all IBM
control codes
2 Suppress LPI, CPI,
MPP and MPL
control codes
3 Suppress CPI and
MPP control codes
4 Suppress LPI and
MPL control codes
5 Suppress print
quality specified in
the PPM command
NOTES
If this command is set to 1,
documents need to be
formatted by sending
transparent control codes to
the printer using Command
Pass-Thru or SCS mode
transparent data.
If value 2 is selected, the
SCS pitch (CPI), line density
(LPI), SHF (MPP), and SVF
(MPL) commands will be
suppressed (not sent to the
printer).
Example: &%Z36,2 no LPI, CPI,
MPP or MPL commands are sent to
the printer. The document prints
using the printer’s defaults.
COMMAND 37: VERTICAL
CHANNEL SELECT (VCS)
Specifies vertical channel select
(VCS) emulation. Functions
similarly to a vertical tab, except the
3287 does LF only.
VALUE DESCRIPTION
0 3287 VCS
emulation
*1 3268/4214/4224
VCS emulation
Example: &%Z37,0 selects 3287
VCS emulation.
*Factory-default setting.