HP (Hewlett-Packard) E1418A TV Converter Box User Manual


 
Command Description
STATus :OPERation:CONDition? Returns the contents of the Operation Status Condition
Register. Reading the register does not affect its contents.
:OPERation:ENABle <
mask>
Specifies which bits of the associated Event Register are
included in bit 7 of the Status Byte Register. The Summary
bit is the bit-for-bit logical AND of the Event Register and the
unmasked bit(s).
:OPERation:ENABle? Returns the value of the mask set for the Operation Status
Register.
:OPERation[:EVENt]? Returns the value of the contents of the Operation Status Event
Register. Reading the register clears all bits in the register.
:PRESet Presets all Enable Registers to 0. The command has no
effect on Condition or Event Registers.
:QUEStionable:CONDition? Returns the value of the Questionable Status Condition
Register. Reading the register does not affect its contents.
:QUEStionable:ENABle <
mask>
Specifies which bits of the associated Event Register are
included in bit 3 of the Status Byte Register. The Summary
bit is the bit-for-bit logical AND of the Event Register and the
unmasked bits.
:QUEStionable:ENABle? Returns the mask set for the Questionable Status Enable
Register.
:QUEStionable[:EVENt]? Returns the value of the Questionable Status Event
Register. Reading the register clears all bits in the register.
SYSTem :ERRor? Returns an error number and message from the
instrument’s error queue.
:VERSion? Returns the SCPI version with which the driver complies.
TEST
:NUMBer? <
number>
Performs a single internal self-test on the module and
returns a 16-bit integer indicating the results of the self-test.
:TST[:RESults]? Returns an array showing the result of all self-tests
performed by the *TST? query.
*TST? Performs all internal self-tests on the module and returns a
16-bit integer indicating the results of the self-test.
TRIGger [:IMMediate] Triggers any channels waiting for trigger when the trigger
source is set to either BUS or HOLD.
:SOURce <
source> Sets the trigger source for the module.
:SOURce? Queries the trigger source for the module.
ABORt Disables the trigger system and places the module in the
idle state.
INITiate[:IMMediate] Changes the trigger system from the idle state to the
wait-for-trigger state.
HP E1418A Command Quick Reference