HP (Hewlett-Packard) E1418A TV Converter Box User Manual


 
Configuration
Example
The following program segment demonstrates how to read the module
identification string and the configuration. The configuration integers are
bit manipulated using the C operator for bit shifting result = result <<1
(a one bit shift to the left).
/** FUNCTION PROTOTYPES **/
void main (void);
void err_handler(ViSession vi, ViStatus x); /* VTL error routine */
void sys_err(ViSession resource); /* Checks for SCPI programming errors */
/** GLOBAL **/
ViStatus err;
ViSession defaultRM, cmd, dac;
void main (void)
{
int i,num_chan,result = {0},config [6]={0};
char buf[256] = { 0 };
/*** Check the module identification ***/
err=viPrintf(dac, “*IDN?\n”); /* request id from the module */
err=viScanf(dac, “%t”, &buf); /* enter string returned */
printf (“Module is identified as a %s\n”, buf); /* print the result */
/*** Get the module configuration ***/
err=viPrintf(dac, “DIAG:CONF?\n”); /* request module configuration */
err=viScanf(dac, “%,6d”, &config); /* returns six integers */
/* Decode the first integer */
result=config[0]; /* Expansion board */
if (result < 7)
{
printf (“Module is a 16 channel device\n”);
num_chan = 16;
}
else
{
printf (“Module is an 8 channel device\n”);
num_chan=8;
}
42 Programming Examples Chapter 2