HP (Hewlett-Packard) E1418A TV Converter Box User Manual


 
General
Characteristics
Settling Time:
300 µS (+full scale to –full scale step, single channel, to accuracy listed
previously)
Isolation (for isolated channels):
42 Vdc/42 V peak (channel-to-chassis or channel-to-channel)
Synchronization:
Software commands, External TTL trigger, or VXIbus TTL Trigger lines
Single channel or multiple channel
VXI Specification:
Device Type: A16 or A24, D16, slave only, register-based
Power
Requirements
Current Required (Amps)
Configuration + 5 V
DC
+ 5 V
Dynamic
+ 12 V
DC
+ 12 V
Dynamic
+ 24 V
DC
+ 24 V
Dynamic
– 24 V
DC
– 24 V
Dynamic
8 Channel
Non-Isolated
0.70 0.01 0.04 0.01 0.44 0.01 0.44 0.01
8 Channel
Isolated
0.75 0.01 0.04 0.01 0.88 0.01 0.00 0.00
16 Channel
Non-Isolated
1.25 0.01 0.04 0.01 0.88 0.01 0.88 0.01
16 Channel
Isolated
1.40 0.01 0.04 0.01 1.60 0.01 0.00 0.00
Cooling
Requirements
For a 10°C rise
Air Flow P
Avg
Watts/slot
8 Channel
configurations
2.0
liters/second
0.10 mm H
2
O 25.4
16 Channel
configurations
3.9
liters/second
0.18 mm H
2
O 49.0
112 HP E1418A Specifications Appendix A