HP (Hewlett-Packard) E1418A TV Converter Box User Manual


 
SOURcen:CURRent[:LEVel]:TRIGgered[:AMPLitude]
SOURcen:CURRent[:LEVel]:TRIGgered[:AMPLitude] <value | MIN | MAX | DEF>
outputs the current set in value at channel n when the trigger conditions are satisfied and
the output relay is closed. Use this command to synchronize multiple channel outputs.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
SOURce
n keyword 1 to 8 or 1 to 16 1
<
value>
numeric (float 32) or
discrete
-0.02 Amps to +0.02 Amps or
MIN | MAX | DEF
0
Comments In the keyword, SOURcen, the valid range of n is:
1 to 8 for E1418A, E1418A Option 002
1 to 16 for E1418A Option 001, E1418A Option 003.
Values of n outside these ranges will generate an error.
The <value> parameter is a floating point 32-bit number in the range of -0.02 A
to +0.02 A.
MIN sets -0.02 Amps.
MAX sets +0.02 Amps.
DEF sets 0 Amps.
This command sets channel n to output the current specified following a valid
trigger condition. Following this command, the trigger system must be enabled
using an
INITiate command. See the TRIGger subsystem discussion on page 54
for additional information.
If the module is in a wait-for-trigger state (INIT has been received) when this
command is received, an error is generated.
The output state of the channel must be enabled and the trigger event satisfied for
the current to appear at the output terminals.
If the channel is in the voltage mode when this command is received, an error is
generated.
Related Commands: SOURcen:CURRent[:LEVel]:TRIGgered[:AMPLitude]?,
SOURcen:FUNCtion:MODE CURRent, OUTPutn[:STATe]
SOURce
Chapter 3 HP E1418A SCPI Command Reference 87