HP (Hewlett-Packard) E1418A TV Converter Box User Manual


 
SOURcen:CURRent[:LEVel][:IMMediate][:AMPLitude]?
SOURcen:CURRent[:LEVel][:IMMediate][:AMPLitude]? [<MIN | MAX | DEF>
queries the last output value written by
SOURcen:CURRent[:LEVel][:IMMediate][:AMPLitude].
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
SOURce
n keyword 1 to 8 or 1 to 16 1
<MIN | MAX | DEF> discrete (optional) MIN | MAX | DEF none
Returns: 32-bit floating point number (float 32).
Comments In the keyword, SOURcen, the valid range of n is:
1 to 8 for E1418A, E1418A Option 002
1 to 16 for E1418A Option 001, E1418A Option 003.
Values of n outside these ranges will generate an error.
If no parameter is given, this query returns the source current set on channel n by
the last
SOURcen:CURRent[:LEVel][:IMMediate][:AMPLitude] command. The
value returned is the value last programmed on that channel, not an actual
measurement of the hardware output value.
If a parameter is given,
MIN returns -0.02 Amps.
MAX returns +0.02 Amps.
DEF returns 0 Amps.
This command generates an error if channel n is in the voltage output mode.
Related Commands: SOURcen:CURRent[:LEVel][:IMMediate][:AMPLitude],
SOURcen:FUNCtion:MODE CURRent
SOURce
86 HP E1418A SCPI Command Reference Chapter 3