HP (Hewlett-Packard) E1418A TV Converter Box User Manual


 
APPLyn:VOLTage
APPLyn:VOLTage <value | MIN | MAX | DEF> outputs a voltage on the specified
channel, n.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
APPLy
n keyword 1 to 8 or 1 to 16 1
<
value>
numeric (float 32) or
discrete
-16 V to +16 V or MIN | MAX | DEF 0
Comments In the keyword, APPLyn, the valid range of n is:
1 to 8 for E1418A, E1418A Option 002
1 to 16 for E1418A Option 001, E1418A Option 003.
Values of n outside these ranges will generate an error.
The <value> parameter can range from -16 Volts to +16 Volts.
MIN sets -16 Volts output.
MAX sets +16 Volts output.
DEF sets 0 Volts output.
This command is affected by the state of the program jumper on the terminal
module for this channel. To use the
APPLyn:VOLT command:
the P/J jumper must be set to program selectable or, if set to jumper selectable,
the V/I jumper must be set to the voltage mode.
This jumper is described on page 31.
Equivalent Commands: SOURcen:FUNCtion:MODE VOLT,
SOURcen:VOLTage[:LEVel][:IMMediate][:AMPLitude], OUTPutn[:STATe] ON
*RST Condition:
If the P/J jumper is set to program selectable:
output mode is set to voltage, 0 volts output, output relay open.
If the P/J jumper is set to jumper selectable:
output mode is set by the V/I jumper, 0 volts or amps, output relay open.
APPLy