LG Electronics STB-3000 DVR User Manual


 
55
206-4272
IP Environment Setup (Cont.)
(Continued on next page)
* PCS150R and later Pro:Centric servers do not support HRC or IRC cable channel frequencies.
(Continued from previous page)
RF Conguration
a) Select/highlight the Media Type eldandpressOK on the Installer Remote to display the
drop-down list of options. Then, use the Up/Down arrow keys to select RF.
Note: IftheMediaTypehasalreadybeensetintheEZ-ManagerWizard,thespeciedvalue
willbereectedinthiseld.
b) For STBs in Pass-through Mode or FTG Mode, if the Data Channel is left at its default value
(AUTO), the STB’s Data Channel Auto Search feature will be enabled. See Installer Menu
item 119 DATA CHANNEL description on page 38 for further information.
To toggle between AUTO or MANUAL settings for the Data Channel, select/highlight the Data
Channel eldandpressOK.
WhentheDataChanneleldissetto“MANUAL,”adataentryeldisavailableonthe
screen, and you can specify the RF channel number that will be used by the Pro:Centric
server as its data channel. The Data Channel value can be set from 0 (disabled) to 135.*
UsethearrowkeysontheInstallerRemotetoselecttheDataChanneldataentryeldand
press OK. You can then use the number keys on the Installer Remote to direct enter the
Data Channel, or you can use the arrow keys to select the appropriate number(s) from the
pop-up virtual keyboard displayed at the bottom of the screen. When you are done, select
Enter from the virtual keyboard, and then press OK on the Installer Remote.
Note: If the Data Channel has already been set in the Installer Menu (Installer Menu item 119)
orintheEZ-ManagerWizard,thespeciedchannelwillappearintheDataChanneldataentry
eld.IfyouchangetheDataChannelinthismenu,InstallerMenuitem119willnowshowthe
value you entered here.
IP Conguration
a) Select/highlight the Media Type eldand press OK on the Installer Remote to display the
drop-down list of options. Then, use the Up/Down arrow keys to select IP. IP Address and
PortNumbereldswillappearonthescreen(inplaceoftheDataChanneleld).
Note: IftheMediaTypehasalreadybeensetintheEZ-ManagerWizard,thespeciedvalue
willbereectedinthiseld.Also,iftheserverIPaddressandportnumberhavealready
beensetintheEZ-ManagerWizard,thespecieddatawillbereectedintheIPAddressand
PortNumberelds.
Note: Setting the Media Type to “IP” automatically sets item 119 DATA CHANNEL in the
Installer Menu to 253. You cannot alter this setting unless you revert Media Type to “RF.”
Also, it is not possible to direct enter “253” in the Installer Menu.
b) Enter the Pro:Centric server IP address and port number in the IP Address and Port Number
elds,respectively.TheIPaddressmustmatchtheIPv4multicastaddressandtheport
number must match the port number that is set in the Pro:Centric server.
Foreachdataentryeld:UsethearrowkeystoselecttheeldandpressOK. Then, you
can either use the number keys on the Installer Remote to direct enter data values or
use the arrow keys to select the appropriate number(s) from the pop-up virtual keyboard
displayed at the bottom of the screen. When you are done, select Enter from the virtual
keyboard, and then press OK on the Installer Remote.