LG Electronics STB-3000 DVR User Manual


 
64
206-4272
Reference: Display Panel Specications
This section describes the types of commercial display panels that may be used with the STB-3000.
LG Hospitality TV Panels
The STB-3000 may be used with LG Hospitality TVs (LY570H, LY560H, etc.) that support Multiple
Protocol Interface (MPI).
Use the MPI/MTI cable provided to connect the RJ-12 DISPLAY CONTROL 2 port on the STB-
3000 front jack panel to the MPI port on the rear jack panel of the display.
LG Commercial Monitors & Public Display TV Panels
The STB-3000 may be used with LG Commercial Monitors (M3203CCBA, M3204C, etc.) or Public
Display TVs (LD450C, LT560C, etc.) that support the TV-Link Monitor (TLM) interface.
Use the 3.5 mm-to-DB9 TLM cable provided to connect the 3.5 mm DISPLAY CONTROL 1 jack
on the STB-3000 rear jack panel to the RS-232 CONTROL connector on the rear jack panel of the
display.
Note that when you use these model display panels, you must set Installer Menu item 113 PANEL
TYPE appropriately. For example, if you are using an LG Commercial Monitor or Public Display TV
that does not support an xb Input Select command, set Installer Menu item 113 to 2. If you are using
an LG Commercial Monitor or Public Display TV that does support an xb Input Select command, set
Installer Menu item 113 to 4 (default).
Note: Installer Menu item 113 values 0, 1, and 3 are available to support legacy panel types.
Commercial Non-LG TV Panels
The STB-3000 may be used with commercial non-LG TVs that support SONIFI’s Multiple Television
Interface (MTI) protocol.
Use the MPI/MTI cable provided to connect the RJ-12 DISPLAY CONTROL 2 port on the STB-3000
front jack panel to the MTI (typically labeled “DATA”) port on the rear jack panel of the display.
Note that some MTI interface configuration may be required on non-LG TVs. Refer to the TV
manufacturer’s documentation to determine if any configuration is required.