RECORDING IMAGES IN THE ALARM
RECORDING AREA
Pre-alarm recording
1
Setting the time
Press the MENU button to display the LANGUAGE/CLOCK SET
menu, and set the date and time. After the setting has been made,
press the EXIT/OSD button, the date and time appear in the
operating display. (See page 44.)
2
Set pre-alarm recording.
Press the MENU button to display the ALARM REC MODE SET
menu. Set ALARM RECORDING to the desired alarm recording
setting (example: ENABLED). The setting for PRE-ALARM
RECORDING will be set to “OFF”, so change it to “ON”. (See page
62.)
Press the EXIT/OSD button to return to the normal screen. “PRE”
appears in the operating display, the ALARM indicator illuminates
and pre-alarm recording starts (the REC mark does not appear).
The same monitored image as in the normal recording area is
recorded repeatedly in the alarm recording area.
Recording onto the hard disk proceeds automatically (default
setting) according to the following settings. The settings can be
changed between long-period recording and high-quality recording
in five steps. (See page 59.)
•
Hard disk recording areas:
Normal recording area: 80%
Alarm recording area: 19%
Archive area: 1%
•
Picture quality: EN (Enhanced)
•
Recording speed: 8.33 FPS (81H)
3
When an alarm is received, pre-alarm recording stops
automatically and the alarm images are recorded.
The “PRE” disappears from the operating display, “ALARM”
flashes and the ALARM indicator flashes.
<LANGUAGE/LANGUE/SPRACHE/IDIOMA>
ENGLISH
<CLOCK SET>
01-01-2002 TUE 00:00:00
<SUMMER TIME SET>
MODE : USE
WEEK MONTH TIME
ON LST-SUN 03 02:00
OFF LST-SUN 10 02:00
<EXT.CLOCK SET>
ADJUST.TIME 01:00
MENU
<ALARM REC MODE SET>
PICTURE QUALITY : SUPER FINE
AUDIO RECORDING : ON
ALARM RECORDING : ENABLED
ALARM INTERLEAVE : ONLY
PROGRAM GROUP : OFF
REC RATE: @ 0.1FPS, DURATION: 40SEC
PRE-ALARM RECORDING : ON
REC RATE:@ *** FPS, DURATION: ***
=> (01010 ALARMS CAN BE RECORDED )
ALARM TRIGGER : ALARM
REC/STOP
ALARM
01
REC PRE 0000 REPEAT EN 10-05-02 18:10:25
ALARM
01
REC ALARM 0001 REPEAT EN 10-06-02 09:30:15
Pre-alarm images
are recorded
Monitored images
are recorded
English
23