Sanyo DSR-3009P DVR User Manual


 
RECORDING SETTING
7
Use the jog dial to move the cursor to T-1, and then turn the
shuttle dial clockwise to set T-2” .
8
Use the jog dial to move the cursor to the “OFF setting for
LEVEL, and then turn the shuttle dial clockwise to set the
sensitivity to “2” .
9
Use the jog dial to move the cursor to MODE, and then turn
the shuttle dial clockwise to select “A” .
10
Use the jog dial to move the cursor to EXIT, and then turn
the shuttle dial clockwise.
The setting is then complete.
11
Press the EXIT/OSD button.
The display returns to the camera image display screen.
If a suspicious person appears in the center of the images from
camera 5, an alarm will be triggered.
Note: You can check the sensitivity in the setting screen. When an
alarm is detected, the buzzer (a beeping noise) sounds. If the
sensitivity is too strong, an alarm can be triggered by variations
in light. Make the setting that is appropriate for the area being
monitored.
Setting the alarm duration
You can set the alarm duration separately for each camera. Separate
settings are only possible when DURATION in the ALARM REC
MODE SET menu is set to INDIV”. (See page 59.)
1
Press the MENU button to select RECORD SET, and then turn
the shuttle dial clockwise.
The RECORD SET sub-menu appears, and the cursor is
positioned at RECORDING AREA SET.
2
Use the jog dial to move the cursor to ALARM OPERATION
SET, and then turn the shuttle dial clockwise.
The ALARM OPERATION SET sub-menu appears, and the cursor
is positioned at MAIN MON. DISPLAY.
3
Use the jog dial to move the cursor to ALARM DURATION
SET, and then turn the shuttle dial clockwise.
The ALARM DURATION SET sub-menu appears, and the cursor
is positioned at 01 (camera 1).
4
Turn the shuttle dial clockwise, use the jog dial to set the
alarm duration (example: 10S), and then turn the shuttle dial
clockwise.
When an alarm is received at camera 1, the alarm will be received
for 5 seconds. The cursor then moves to camera 2.
Display examples:
5S – 15M: The same duration has been set for all cameras.
CC: Operates while an alarm is being received (minimum
1 second).
01 T-2 LEVEL:OFF MODE A EXIT
01 T-2 LEVEL:2 MODE A EXIT
01 T-2 LEVEL:5 MODE A EXIT
01 T-2 LEVEL:5 MODE A EXIT
EXIT/OSD
MENU
<ALARM OPERATION SET>
MAIN MON. DISPLAY : 9
ALARM PRIORITY : FIRST
MON.2 DISPLAY : OFF
RETRIGGER : OFF
MOTION SENSOR ->
ALARM DURATION SET ->
<ALARM DURATION SET>
IN IN IN IN
01:5S 02:5S 03:5S 04:5S
05:5S 06:5S 07:5S 08:5S
09:5S 10:5S 11:5S 12:5S
13:5S 14:5S 15:5S 16:5S
68
English