Sanyo DSR-3009P DVR User Manual


 
RECORDING SETTING
Alarm trigger setting
1
Use the jog dial to move the cursor to the ALARM TRIGGER
setting.
2
Turn the shuttle dial clockwise, use the jog dial to select the
method of detecting intruders (example: SENSOR), and
then turn the shuttle dial clockwise.
The cursor moves to PICTURE QUALITY.
Display examples: Alarm recording trigger settings
ALARM: Alarm recording is carried out when an external alarm
(when a switch is connected to the ALARM IN terminals at the
rear of the digital video recorder for open/close operation
occurs).
SENSOR: Alarm recording is only carried out when the motion
sensor detects a moving object. Refer to motion sensor
settings. (See page 67.)
ALARM AND SENSOR: Alarm recording is carried out when
there is a response from both an external alarm and a built-in
motion sensor.
ALARM OR SENSOR: Alarm recording is carried out when
there is a response from either an external alarm or a built-in
motion sensor.
Note:
MOTION SENSOR settings must be made if SENSOR, ALARM
AND SENSOR or ALARM OR SENSOR is selected.
The digital video recorders built-in motion sensor cannot be used
if a multiplexer is connected to the digital video recorder.
If using the built-in sensor of a multiplexer, the alarm output should
be directed to the alarm input of the digital video recorder in order
to record alarms.
If you stop recording while alarm recording that has been triggered
by a motion sensor is in progress, move the cursor to the ALARM
OPERATION SET setting in the menu screen and then turn the
shuttle dial clockwise. The motion sensor screen appears, so use
this screen to change the LEVEL setting to OFF”.
<ALARM REC MODE SET>
PICTURE QUALITY : SUPER FINE
AUDIO RECORDING : ON
ALARM RECORDING : ENABLED
ALARM INTERLEAVE : ONLY
PROGRAM GROUP : OFF
REC RATE: @ 8.33FPS, DURATION: 5SEC
PRE-ALARM RECORDING : ON
REC RATE: @ 12.5FPS, DURATION: 5
=> (01010 ALARMS CAN BE RECORDED )
ALARM TRIGGER : ALARM
ALARM
RECORDING
:
ENABLED
ALARM INTERLEAVE : ONLY
PROGRAM GROUP : OFF
REC RATE: @ 8.33FPS, DURATION: 5SEC
PRE-ALARM RECORDING : ON
REC RATE: @ 12.5FPS, DURATION: 5
=> (01010 ALARMS CAN BE RECORDED )
ALARM TRIGGER : SENSOR
English
63