Sanyo DSR - 300 DVR User Manual


 
24 English
OPERATION
4 ALARM AND PRE-ALARM RECORDING
Follow the procedures below to have the digital video
recorder record an alarm image only when alarm input is
detected.
z Confirm that the cable of the device required for alarms
is connected to the ALARM terminal. (JP. 16)
z When the motion sensor is set, an alarm image is
recorded when a moving subject is detected. (JP. 67)
1 Set alarm recording.
The default settings are shown below.
See P. 65 for how to change these settings.
z “ALARM RECORDING”: “OFF”
Alarm recording is disabled.
z “DURATION”: “1 SEC”
Recording is performed for 1 second for each alarm
signal received while the alarm is set.
2 When alarm input is detected
When an alarm is generated, the display below appears in
the operation display area, and an alarm image is
recorded.
z “ALARM” appears in the operation display area.
z When an alarm is generated on a channel that is
already alarm recording, the alarm recording time is
extended counting from that moment. The new alarm is
not counted.
z The latest 9,999 alarms are displayed in the alarm
history (recording list). (Although the history can record
up to 16,000 items, only 9,999 of these can be
displayed on-screen.)
z The panel’s ALARM indicator flashes.
z If an alarm occurs during normal recording or timer
recording, the recording operation will be ended, and it
will restart after the end of alarm recording.
z When the normal recording area is set to “*1%”, alarm
recording is possible for the complete memory available
in the alarm recording area. For “1%” and other
settings, up to 16,000 items are recorded per hard disk.
However, if set for *1%, “ALARM SEARCH”, “ALARM
THUMBNAIL SEARCH”, and “MOTION DETECTION
SEARCH” will not be available. Use “TIME/DATE
SEARCH” instead.
Furthermore, since the alarm skip function will also be
inactive, it will be necessary to carry out fast-forward
and fast-rewind playback.
3 End alarm recording.
When the alarm duration time ends (default setting: 1
second), “ALARM” disappears from the operation display,
the ALARM indicator stops flashing, and recording stops.
z When the space remaining in the alarm recording area
drops below the setting value, the FULL indicator lights
and recording stops. You can start recording from the
beginning again by changing the recording setting.
(JP. 57)
If recording is ended during alarm recording
using the motion sensor
Set “LEVEL” from the motion sensor screen to “OFF”.
(JP. 67)
[EXIT/OSD] button
ALARM FULL indicator
ALARM indicator
FULL indicator
Alarm recording
Counts the number
of alarms.
z
05- 10- 04 ALARM 0001
10: 50: 00 EN 10FPS
e00_l8had_us_7.book Page 24 Wednesday, March 10, 2004 2:47 PM