Sanyo DSR - 300 DVR User Manual


 
ALARM REC MODE SET8
English 65
[Settings] ( indicates default setting.)
[Setting conditions]
z This can be set whenever the recording rate is 10.00
FPS or more for field recording, or 5.00 FPS or more for
frame recording.
7 Move the cursor to “ALARM
RECORDING” and press the [ ] button,
then press the [ ] or [ ] button to
change the setting.
[Settings] ( indicates default setting.)
* “DLY AL-REC ON TMR” is enabled just by making timer
settings. There is no need to press the [TIMER] button.
8 Move the cursor to “REC RATE” and
“DURATION” and press the [ ] button,
then press the [ ] or [ ] button to
change the setting.
The maximum number of images (shown in parentheses)
changes in accordance with the new settings.
[Settings]
*CC: Operates while an alarm is being activated.
Press the [EXIT/OSD] button.
The display returns to the normal screen.
“ALARM” appears in the operation display area.
When an alarm occurs, the number of alarms is displayed.
z If a new alarm occurs during alarm recording
Recording switches from the previous alarm image to
the new alarm image in a seamless process. If a
number of different alarms occur, these are treated as a
single alarm until an alarm interruption occurs.
z Settings cannot be made for “PRE-ALARM
RECORDING” when “ALARM RECORDING” is set to
“OFF”.
z The alarm history (recording list) displays up to the last
9,999 items. (Although the history can record up to
16,000 items, only 9,999 of these can be displayed on-
screen.)
z When the normal recording area is set to “*1%”, alarm
recording is performed for as long as space is left in the
alarm recording area. For “1%” and other settings, up to
16,000 items are recorded per hard disk.
Setting Description
OFF Audio recording is not carried out
ON Audio recording is carried out
Setting Description
OFF Does not perform alarm recording.
ENABLED
Always performs alarm recording, regardless
of whether or not timer recording is being
performed.
AL-REC ON
TIMER
Performs alarm recording only during timer
recording.
AL-REC OFF
TIMER
Performs alarm recording only when timer
recording is not being performed.
*DLY AL-REC
ON TMR
Performs alarm recording only for the amount
of time set by the timer. Normal recording is
not performed.
Maximum
number of
images
Setting Description
REC RATE
60.00 to 0.03 FPS (for
field recording)
30.00 to 0.02 FPS (for
frame recording)
Sets the recording
rate.
DURATION
1 second to 15 minutes,
*CC
Sets the recording
time per alarm.
When alarm recording settings have been
completed
Number of alarm
recordings
Alarm display
10- 20- 04 ALARM 0000
08: 30: 00 EN 10
FPS