Chapter 3
Electrical Connections
3.1 Introduction
The 7829 Viscomaster
®
/ Viscomaster Dynamic
™
viscosity meter has two types of output:
• Two 4-20mA analog outputs
The Viscomaster Dynamic has a single fully configurable output proportional to a
user-specified parameter. The Viscomaster has two fully configurable outputs.
The parameters that can be output on each analog output are as follows:
Note: In all cases, the limit values of each analog output are configurable.
• A Modbus (RS-485) interface, giving access to other measurement results, system information
and configuration parameters. The Modbus interface is also used to configure the meter, using
a PC running the Micro Motion ADView or ProLink II software (see Using ADView and
ProLink II chapter).
For installations in hazardous areas:
• For ATEX installations, the electrical installation must strictly adhere to the safety information
given in the ATEX safety instructions booklet shipped with this manual. See Section 1.1 for
important information.
• For installations in USA and Canada, the electrical installation must strictly adhere to the Electrical
Codes and a conduit seal is required within 2” (50 mm) of the enclosure.
Viscomaster Dynamic Viscomaster
Analog Output 1 Analog Output 2 Analog Output 1 Analog Output 2
Dynamic viscosity (cP) Temperature
(1)
(1) Factory default selection.
Dynamic viscosity (cP) Dynamic viscosity (cP)
Kinematic viscosity (cSt)
(1)
Kinematic viscosity (cSt)
(1)
Kinematic viscosity (cSt)
Line density Temperature
Temperature
(1)
Temperature Line density Line density
Referred density Referred density
Referred viscosity Referred viscosity
CII CII
CCAI CCAI