Firmware Error Codes
If you replace FRUs and the problem is still not corrected, go to MAP 0030 in the
Diagnostics Information for Multiple Bus Systems unless otherwise indicated in the
tables.
Table 3-2 (Page 1 of 9). Firmware Error Codes.
Error Code Description Action/
Possible Failing FRU
20100xxx Power Supply
20A80xxx Remote initial program load (RIPL)
error
xxx=000 Insufficient information to boot. Verify the IP address.
001 Client IP address is already in use by
other network device
Change IP address.
002 Cannot get gateway IP address Refer to “Firmware Checkpoints” on
page 3-14 table using code F74.
003 Cannot get server hardware address Refer to “Firmware Checkpoints” on
page 3-14 table using code F74.
004 Bootp failed Refer to “Firmware Checkpoints” on
page 3-14 table using code F75.
005 File transmission (TFTP) failed Check network connection, try again.
20D00xxx Unknown/Unrecognized device
xxx=00F Self-test failed on device, no
SRN/location code information available
Check the System Management
Services error log entry (if present) for
the location code of the failing device.
The error log is described in “Step
1020-4” on page 2-11
If the error code specifies a network
adapter, see 3-1.
010 Self-test failed on device, can't locate
package.
Contact your service support
representative for assistance.
20E00xxx Security
xxx=000 Power on Password entry error. Retry installing the password.
001 Privileged-access password entry error. Retry installing the password.
002 Privileged-access password jumper not
enabled.
The privileged-access password jumper
is not in the correct position for
password initial entry.
Consult the system's User's Guide for
jumper location and position.
3-4 7043 43P Series Service Guide