IBM RS/6000 7043 43P Home Theater Server User Manual


 
Table 4-1 (Page 9 of 11). Firmware Error Codes
Error Code Function /
Description
Repair Action/Possible Failing FRU
25AA0007 Unable to lock
eeprom
Refer to EEPROM problem resolution above
Memory errors
Use the location code obtained from the SMS Error Log utility (described in Map Step 1020-4) to
identify which memory DIMM the error is reported against.
Memory error codes are in the form 25Cyyrrr where yy indicates Memory DIMM PD-bits and rrr
indicates the last three digits of the error code.
See “Memory PD Bits” on page 4-14 for information on how to interpret PD bits.
25Cyy002 Memory DIMM failed
memory test
1. Replace Memory DIMM
2. Replace System Planar
See “Memory PD Bits” on page 4-14 for
information on how to interpret PD bits.
PCI adapter problem
26020001 Invalid PCI adapter
Vendor ID
1. Move card to another slot
2. Run AIX adapter diagnostics
3. Replace card
4. Update system firmware
5. Replace power supply
26020002 Invalid PCI adapter
Device ID
1. Move card to another slot
2. Run AIX adapter diagnostics
3. Replace card
4. Update system firmware
5. Replace power supply
26020003 Invalid PCI adapter
Class Code
1. Move card to another slot
2. Run AIX adapter diagnostics
3. Replace card
4. Update system firmware
5. Replace power supply
26020004 Invalid PCI adapter
ROM VPD Structure
1. Update card firmware
2. Move card to another slot
3. Run AIX adapter diagnostics
4. Replace card
5. Update system firmware
6. Replace power supply
26020005 PCI adapter
firmware is too large
to load
1. Update card firmware
2. Move card to another slot
3. Run AIX adapter diagnostics
4. Replace card
5. Update system firmware
6. Replace power supply
Chapter 4. Error Code to FRU Index for the Model 150 4-9