IBM RS/6000 7043 43P Home Theater Server User Manual


 
Step 1540A-15
Does the system have adapters or devices that require supplemental media?
NO Go to “Step 1540A-16.”
YES Go to “Step 1540A-17.”
Step 1540A-16
Consult the PCI adapter configuration documentation for your operating system to
verify that all installed adapters are configured correctly.
Go to "MAP 0410: Repair Checkout" in the Diagnostics Information for Multiple Bus
Systems.
If the symptom did not change and all the FRUs have been exchanged, call your
service support person for assistance.
Step 1540A-17
Select TASK SELECTION.
Select Process Supplemental Media and follow the on screen instructions to process
the media.
Supplemental media must be loaded and processed one at a time.
Did the system return to the TASK SELECTION list after the supplemental
media was processed?
NO Go to “Step 1540A-18” on page 2-38.
YES Press F3 to return to the FUNCTION SELECTION screen.
Go to “Step 1540A-13” substep 4 on page 2-35.
Chapter 2. Maintenance Analysis Procedures (MAPs) 2-37